Heat Transfer Fluids

D2C & Industrial liquid cooling

Heat Transfer Fluids

Heat transfer fluids carry thermal energy through a circulating system, moving heat from equipment to a heat exchanger or another part of the process. Performance depends on the fluid properties, operating temperature, flow conditions and compatibility with the complete cooling circuit.

Krayden supplies DOWFROST™ heat transfer technology, including DOWFROST™ LC 25 for appropriate direct-to-chip and technology cooling systems. These inhibited propylene glycol fluids support heat transfer and corrosion management within their specified application conditions.

Select the fluid against the equipment manufacturer's requirements, loop metallurgy, elastomers, freeze protection and maintenance plan. Glycol-water coolants and dielectric immersion fluids require separate evaluation. Contact our technical team →

Frequently asked questions

What is a heat transfer fluid used for?

It absorbs and transports heat within a circulating system. Examples include industrial process cooling and cold-plate loops for electronics. Heat is ultimately rejected through a heat exchanger or another cooling stage; the fluid forms part of that system.

What is DOWFROST LC 25?

DOWFROST LC 25 is a ready-to-use heat transfer fluid formulated with 25% propylene glycol by volume and corrosion inhibitors. It is intended for appropriate technology cooling applications, including direct-to-chip loops. Confirm the equipment and fluid requirements for the installation.

Can a glycol-based coolant be used for immersion cooling?

Do not assume it can. Glycol-water coolants are generally used inside contained cooling circuits and are not dielectric immersion fluids. Direct contact with energized electronics requires a fluid specifically evaluated for that purpose and for the complete system.

Should DOWFROST LC 25 be diluted before use?

It is supplied as a ready-to-use formulation. Adding water changes the glycol and inhibitor concentrations and can affect freeze protection and corrosion control. Follow the product guidance and the cooling-equipment specification before making any concentration adjustment.

Does increasing glycol concentration always improve performance?

No. Concentration affects freeze protection, viscosity, heat capacity and heat-transfer behavior. A higher concentration can increase pumping demand and alter cooling performance. Use the specified formulation and concentration for the required operating conditions.

What should be checked during fluid maintenance?

Follow the supplier and equipment maintenance plans. Checks may include concentration, pH, inhibitor condition, contamination and signs of corrosion. Establish a baseline after commissioning and avoid mixing fluid brands or chemistries without a documented compatibility review.


Learn more

Move heat through the cooling loop

A liquid-cooling circuit connects the heat source, cold plate, pumps, distribution hardware and heat exchanger. The fluid must perform across all wetted components, including seals and hoses.

For direct-to-chip systems, review the technology cooling loop separately from facility-side cooling. Their temperature, water quality and material requirements may differ even when both are part of the same installation.

Illustrative direct-to-chip cooling loop with copper cold plates, hoses, manifold and coolant sight glass

Select for the complete system

The correct fluid depends on more than cooling capacity.

  • Identify the cooling architecture and required fluid specification.
  • Review minimum, normal and maximum fluid temperatures.
  • Check metals, coatings, elastomers and plastic components.
  • Assess freeze protection, flow rate and pumping requirements.

Plan commissioning and maintenance

System condition affects fluid life and thermal performance.

  • Clean and flush the loop using an approved procedure.
  • Confirm fill quality and prevent cross-contamination.
  • Record the initial fluid condition and concentration.
  • Monitor the loop and follow the specified service plan.

Cooling architectures and fluid selection

Application Fluid consideration Review point
Direct-to-chip technology cooling DOWFROST™ LC 25 is a ready-to-use inhibited PG25 option. Confirm equipment approval, loop materials and operating conditions.
Industrial closed-loop cooling Choose a heat transfer grade suited to the required process. Review temperature range, freeze protection, corrosion control and maintenance.
Facility-side cooling Follow the facility equipment and water-treatment specification. Do not assume the technology-loop fluid specification also applies.
Immersion cooling Evaluate a dedicated dielectric fluid. Glycol-water cooling fluids are not interchangeable with immersion fluids.

Match fluid chemistry to equipment guidance

Provide the required fluid specification, operating conditions, system volume and wetted-material list when requesting a recommendation. This helps identify an appropriate grade and a practical fill and maintenance approach.

Need help matching materials or equipment to your application? Contact our technical team →